RTE-P1, -B1

ON-Delay 1 (power start) When voltage is applied to the coil, the relay contacts remain in the off state and the set time begins. When the set time has elapsed, the relay contacts transfer to the on state. The contacts remain in the on state until the timer is reset. The timer is reset by removing the coil voltage. Applicable models: RTE P(B)1, GT3A-1, -2, -3, GT3D-1, -2, -3, -4, and GE1A.
Interval 1 (power start) When voltage is applied to the coil, the relay contacts transfer immediately to the on state and the set time begins. When the set time has elapsed, the relay contacts transfer to the off state. The contacts remain in the off state until the timer is reset. The timer is reset by removing the coil voltage. Applicable models: RTE-P(B)1, GT3A-1, -2, -3, and GT3D-1, -2, -3, -4.
Cycle 1 (power start, OFF first) When voltage is applied to the coil, the contacts remain in the off state and the set time begins. At the end of the set time, the contacts transfer to the on state and remain in the on state until the set time elapses. The timer cycles between the two states until power is removed from the coil. Removing the coil voltage resets the timer. The set time for both the on state and the off state is the same. Applicable models: GT3A-1, -2, -3, GT3D-1, -2, -3, -4 and RTE-P(B)1.
Cycle 3 (power start, ON first) When voltage is applied to the coil, the contacts immediately transfer to the on state and the set time begins. At the end of the set time, the contacts transfer to the off state and remain in the off state until the set time elapses. The timer cycles between the two states until power is removed from the coil. Removing the coil voltage resets the timer. The set time for both the off state and the on state is the same. Applicable models: GT3A-1, -2, -3, GT3D-1, -2, -3, -4 and RTE-P(B)1.

RTE-P2, -B2

 ON-Delay 2 (signal start) Voltage is applied to the coil at all times. When a start input is supplied, the relay contacts remain in the off state and the set time begins. When the set time has elapsed, the relay contacts transfer to the on state. The contacts remain in the on state until the timer is reset. The timer is reset by applying a reset input or by removing the coil voltage. Applicable models: GT3A-4, GT3D-4and RTE-P(B) 2.
Cycle 2 (signal start, OFF first) Voltage is applied to the coil at all times. When a start signal is supplied, the relay contacts remain in the off state and the set time begins. At the end of the set time, the contacts transfer to the on state and remain in the on state until the set time elapses. The timer cycles between the two states until the timer is reset. The set time for both the on state and the off state are the same. The timer is reset by application of a reset input or by removing coil voltage. Applicable models: GT3A-4, GT3D-4 and RTE-P(B) 2.
Cycle 4 (signal start, ON first) When the start input turns on while power is on, the NO contact goes on. The output oscillates at a preset cycle (duty ratio 1:1).
Signal ON/OFF-Delay 1 Voltage is supplied to the coil at all times. When a maintained start signal is supplied, the contacts immediately transfer to the on state and the set time begins. When the set time has elapsed, the contacts transfer to the off state. The contacts remain in the off state until the start signal is removed. The contacts transfer back to the on state and remain in the on state for the set time. When the set time has elapsed, the contacts transfer to the off state and remain in the off state until the start signal is supplied again (no reset is necessary). The timer is reset by application of a reset input or by removing coil voltage. Applicable models: GT3A-4, GT3D-4 and RTE-R(B)2.
Signal OFF-Delay 1 Voltage is applied to the coil at all times. When a start signal is supplied, the contacts immediately transfer to the on state. The set time begins when the start signal is removed. When the set time has elapsed, the contacts transfer to the off state. The contacts remain in the off state until the next start signal is supplied (no reset is necessary). The timer can be reset by application of a reset input or by removing coil voltage. Applicable models: RTE-P(B)2, GT3A-4, andGT3D-4.
One Shot 2 (signal start) Voltage is applied to the coil at all times. When a start signal is supplied, the contacts immediately transfer to the on state and the set time begins. If another start signal is supplied (before set time has elapsed), the set time will not be affected. When the set time has elapsed, the contacts transfer back to the off state. The contacts remain in the off state until the next start signal is supplied (no reset is necessary). The timer can be reset by application of a reset input or by removing coil voltage. Applicable models: GT3A-6, GT3D-4, and RTE-P(B)2.


ECD has a large inventory of automation and control products in stock and ready to ship including IDEC Timers. Call ECD today for all your IDEC Timer needs.

Interested in this item?
Click here or Call us at 1.800.947.0868

Please call for quantity discounts, accessories and other configurations.

Click on Column Header to Sort

Part #Terminal StyleFunction GroupInput VoltageRecommended SocketContact ConfigurationPrice 
RTE-B1AD24 Blade On delay, Interval, Cycle OFF, Cycle ON24V AC/DCSR3B-05CDPDT:10A,240VAC$46.87
RTE-B1AF20 BladeOn delay, Interval, Cycle OFF, Cycle ON100-240VACSR3B-05CDPDT:10A,240VAC$46.87
RTE-B1D12 BladeOn delay, Interval, Cycle OFF, Cycle ON12V DCSR3B-05CDPDT:10A,240VAC$46.87
RTE-B2AD24 Blade On delay, Cycle OFF, Cycle ON, signal ON/OFF delay, OFF delay, one shot. 24V AC/DCSR3B-05CDPDT:10A,240VAC$50.07
RTE-B2AF20 BladeOn delay, Cycle OFF, Cycle ON, signal ON/OFF delay, OFF delay, one shot.100-240VACSR3B-05CDPDT:10A,240VAC$50.07
RTE-B2D12 BladeOn delay, Cycle OFF, Cycle ON, signal ON/OFF delay, OFF delay, one shot.12V DCSR3B-05CDPDT:10A,240VAC$50.07
RTE-P1AD24 PinOn delay, Interval, Cycle OFF, Cycle ON24V AC/DCSR2P-06CDPDT:10A,240VAC$40.49
RTE-P1AF20 PinOn delay, Interval, Cycle OFF, Cycle ON100-240VACSR2P-06CDPDT:10A,240VAC$40.49
RTE-P1D12 PinOn delay, Interval, Cycle OFF, Cycle ON12V DCSR2P-05CDPDT:10A,240VAC$40.49
RTE-P2AD24 PinOn delay, Cycle OFF, Cycle ON, signal ON/OFF delay, OFF delay, one shot.24V AC/DCSR3B-05CDPDT:10A,240VAC$50.07
RTE-P2AF20 PinOn delay, Cycle OFF, Cycle ON, signal ON/OFF delay, OFF delay, one shot.100-240VACSR3B-05CDPDT:10A,240VAC$50.07
RTE-P2D12 PinOn delay, Cycle OFF, Cycle ON, signal ON/OFF delay, OFF delay, one shot.12V DCSR3B-05CDPDT:10A,240VAC$50.07