Home // General Machinery Drive Accessories - ACS310 / ACS355

General Machinery Drive Accessories - ACS310 / ACS355

General Machinery Drive Accessories - ACS310 / ACS355

ABB Drives

There are many options available for use with the ABB ACS310 and ACS355 series variable speed AC motor drives including Control Panels, Panel Mounting Kits, Enclosure Kits, Relay Output Extensions, Pulse Encoder Interface Modules and Modbus/Ethernet adapters.

ECD has a large inventory of automation and control products in stock and ready to ship including ABB Variable Speed Drives and Accessories. Call ECD today for all your ABB Drives and Accessory needs.

Interested in this item?
Click here or Call us at 1.800.947.0868

Please call for quantity discounts, accessories and other configurations.

Click on Column Header to Sort

Part #Drive ClassNameDescription 
MTAC-01 ACS355Pulse Encoder InterfaceThe pulse Encoder Interface module offers a differential or single ended interface for a digital pulse encoder connection. VDC signal with a maximum frequency of 200kHz. Get A Quote
MPOT-01 ACS355Speed Pot, Start/Stop & Fw/Rev SwitchesPotentiometer with two switches: Start/Stop and Froward/Reverse. Polarity is selected with DIP switches. No external power source is needed for the potentiometer. This option can be used with the Blank Cover, Basic or Advanced panel. Get A Quote
MPOW-01 ACS355Auxilliary Power ModuleThe optional auxilliary power module provides auxilliary voltage to the control panel, fieldbus, and I/O. Get A Quote
FDNA-01-KIT ACS355DeviceNet AdapterThe DeviceNet network uses a linear bus topology. Terminating resistors are required on each end of the trunk line. Drop lines as long as 6 meters (20 feet) each are permitted, allowing one or more nodes to be attached. DeviceNet allows branching structures only on drop lines. Get A Quote
FPBA-01-KIT ACS355PROFIBUS-DP AdapterPROFIBUS is an open serial communication standard that enables data exchange between all kinds of automation components. The physical transmission medium of the bus is a twisted pair cable (according to the RS-485 standard). The maximum length of the bus cable is 100 to 1200 meters, depending on the selected transmission rate. Up to 31 stations can be connected to the same PROFIBUS system without the use of repeaters. Get A Quote
FCAN-01-KIT ACS355CANopen AdapterCANopen is a higher layer protocol based on the CAN (Control Area Network) serial bus system and the CAL (CAN Application Layer). CANopen assumes that the hardware of the connected device has a CAN transceiver and a CAN controller as specified in ISO 11898. The CANopen Communication Profile, CiA Ds301, includes both cyclic and event driven communication, which makes it possible to reduce the bus load to minimum while still maintaining extremelky short reaction times. High communication performan Get A Quote
FMBA-01-KIT ACS355Modbus RTU AdapterModbus is a serial, asynchronous protocol. The Modbus protocol does not specify the physical interface. Typical physical interfaces are RS-232 and RS-485. The FMBA-01 provides a galvanically isolated RS-485 interface. Modbus is designed for integration with Modicon PLCs or other automation devices, and the services closely correspond to the PLC architecture. The FMBA-01 supports the RTU protocol only. Get A Quote
FENA-01-KIT ACS355Ethernet IP/Modbus TCP AdapterThe FENA-01 module supports both Modbus-TCP and Ethernet/IP network protocols. The Modbus-TCP protocol is simply the Modbus protocol used on top of Ethernet-TCP/IP. Modbus-TCP is an open industrial EtherNet network which has been specified by the Modbus-IDA User Organization. EtherNet/IP is based on the Common Industrial Protocol (CIP), which is also the framework for both the ControlNet and DeviceNet network protocols. The FENA-01 supports 10/100 Mbps transfer rate with network connections made Get A Quote
SREA-01-KIT ACS355 and ACS310Ethernet Adapter (Gateway)SREA-01 is an optional device for web browser based remote interface to the ACS310 and ACS355 drives via Ethernet. This din rail mounted adapter enables remote data acquisition through a standard web browser, utilizing an internal web server for drive configuration and access. Multiple drives (up to 10) can be connected to the Modbus-RTU network through the drive’s Modbus-RTU port. The ACS350 and ACS550 can also be connected through the control panel port, although an additional RS-485 converter Get A Quote
FRSA-00 ACS355Modbus RTU PCBSimilar to the FMBA-01-KIT except as a bare, coated printed circuit board (PCB) with the RS-485 GND as the same potential as the drive I/O GND. Get A Quote
MFDT-01 ACS355FlashDropFlashDrop is a powerful palm sized tool for fast and easy parameter selecting and setting. It gives the possibility to hide selected parameters to protect the machine. Only the parameters needed in the application are shown. The tool can upload/download parameters, copy parameters between two drives or between a PC and a drive. Includes DrivePM (Drive Parameter Manager) which is a software tool to create, edit and copy parameter sets for FlashDrop. The parameter sets can consist of all parameter Get A Quote
ACS-CP-A ACS355Advanced Control PanelThe Advanced Control Panel includes a full graphic, backlite display capable of displaying three Actual Signal values or bar graphs. The Alpha-Numeric display supports thirteen languages. A Real Time Clock is also included. This panel supports the internal Sequence Programming Function. Get A Quote
ACS-CP-C ACS355Basic Control PanelThe Basic Control Panel includes a single line numeric backlit LCD display. Get A Quote
OPMP-01 ACS355 and ACS310Cabinet Panel MountingControl Panel Mounting Platform allows remote mounting of the keypad on a larger enclosure or remote panel. The kit maintains UL Type 12 integrity of the mounting location. Adapters, 3m (10 ft) cable and mounting hardware are included in this kit. With this mounting arrangement, the keypad is removable from the panel in a fashion identical to a drive-mounted keypad. Get A Quote
ACS/H-CP-EXT ACS355 and acs310Control Panel MountingControl Panel Mounting Kit for the drives allows remote mounting of the keypad on the door of an enclosure. The kit includes a 10ft (3m) CAT 5 patch cable, gasket for NEMA 12, mounting hardware and drilling template. Get A Quote
OPCA-01 ACS355 and ACS310RJ45/DB9 AdapterThis adapter converts the drive’s panel port RJ45 (CAT 5 cable connector) plug to a 9 pin RS-232 computer serial port connector for connecting the drive to a PC. Get A Quote
3AFE64532871 ACS355DriveWindow Light 2.xDriveWindow Light is software designed for online drive commissioning and maintenance purposes. It is possible to adjust parameters, read the actual values and control the drive with DriveWindow Light instead of the drive control panel. It is also possible to follow trends and draw graphs. An RJ45 to DB9 adapter cable (OPCA-01) is provided to permit connection between the panel port and a PC. Get A Quote
3AUA0000041141 ACS355DriveBrowserDriveBrowser software is designed for online drive commissioning and maintenance purposes. DriveBrowser uses a computer’s standard Ethernet port to connect to an EtherNet/IP or Modbus-TCP network. It is compatible with the ACS350, ACS550, ACH550, and ACS800* drives (*ACS800 standard control program). Drives require configuration and connection to an EtherNet/IP or Modbus-TCP network. DriveBrowser supports Microsoft Windows operating systems (Windows NT4, 2000, XP &Vista). Configure network conn Get A Quote
SECG-01 ACS355Ethernet to ControlNet GatewaySECG-01 (EtherNet/IP to ControlNet)—will allow a DriveBrowser user to connect a PC’s Ethernet port to drives on a ControlNet networks. Get A Quote
SEDG-01 ACS355Ethernet to DeviceNet GatewaySEDG-01 (EtherNet/IP to DeviceNet)—will allow a DriveBrowser user to connect a PC’s Ethernet port to drives on a DeviceNet networks. Get A Quote
OCAT-01 ACS355Panel Extension Cable7 foot CAT 5 patch cable allows remote operation of the standard panel or connection of the drive to a PC using the RJ45/DB9 Adapter (OPCA-01) which must be purchased separately. Get A Quote
MUL1-R1 ACS355 and acs310NEMA 1 Enclosure KitThis option provides the necessary hardware to modify the ACS310 or ACS 350 drive from the standard fingersafe protected chasis to NEMA 1 protection capable of landing conduit. MUL1-R1 kit is used with frame sizes R0 through R2. Get A Quote
MUL1-R3 ACS355 and ACS310NEMA 1 Enclosure KitThis option provides the necessary hardware to modify the ACS310 or ACS 350 drive from the standard fingersafe protected chasis to NEMA 1 protection capable of landing conduit. MUL1-R3 is used with frame size R3. Get A Quote
MUL1-R4 ACS355 and ACS310NEMA 1 Enclosure KitThis option provides the necessary hardware to modify the ACS310 or ACS 350 drive from the standard fingersafe protected chasis to NEMA 1 protection capable of landing conduit. MUL1-R4 is used with frame size R4. Get A Quote
ACS/H-CP-EXT-IP66 ACS355 and ACS310NEMA 4X Cabinet Panel MountingAllows remote mounting of the ACS-CP-X Operator Panels on a larger NEMA 4X (IP66) enclosure or remote panel. The kit maintains NEMA 4X integrity of the mounting location. All necessary hardware and a mounting template are provided in addition to a 3m panel cable. When mounted, the operator is not removable from the front of the enclosure. The operator panel must be purchased separately. Get A Quote
MREL-01 ACS355 and ACS310Relay Output Module ExtensionThe Relay Output Extention module (MREL) is an interface for connecting three (3) FORM C relay outputs. The MREL-01 is supported from SW version 2.57C and onwards for the ACS350 and is supported by all SW version of ACS310. Get A Quote